Export limit exceeded: 13663 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (13663 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-14133 1 Linksys 12 Re6250, Re6250 Firmware, Re6300 and 9 more 2025-12-10 8.8 High
A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this vulnerability is the function AP_get_wireless_clientlist_setClientsName of the file mod_form.so. Performing manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14135 1 Linksys 12 Re6250, Re6250 Firmware, Re6300 and 9 more 2025-12-10 8.8 High
A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14136 1 Linksys 12 Re6250, Re6250 Firmware, Re6300 and 9 more 2025-12-10 8.8 High
A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-42877 1 Sap 3 Content Server, Internet Communication Manager, Web Dispatcher 2025-12-09 7.5 High
SAP Web Dispatcher, Internet Communication Manager (ICM), and SAP Content Server allow an unauthenticated user to exploit logical errors that lead to a memory corruption vulnerability. This results in high impact on the availability with no impact on confidentiality or integrity of the application.
CVE-2025-64331 1 Oisf 1 Suricata 2025-12-08 7.5 High
Suricata is a network IDS, IPS and NSM engine developed by the OISF (Open Information Security Foundation) and the Suricata community. Prior to versions 7.0.13 and 8.0.2, a stack overflow can occur on large HTTP file transfers if the user has increased the HTTP response body limit and enabled the logging of printable http bodies. This issue has been patched in versions 7.0.13 and 8.0.2. A workaround for this issue involves using default HTTP response body limits and/or disabling http-body-printable logging; body logging is disabled by default.
CVE-2025-8854 2 Bullet3 Project, Bulletphysics 2 Bullet3, Pybullet 2025-12-08 9.8 Critical
Stack-based buffer overflow in LoadOFF in bulletphysics bullet3 before 3.26 on all platforms allows remote attackers to execute arbitrary code via a crafted OFF file with an overlong initial token processed by the VHACD test utility or invoked indirectly through PyBullet's vhacd function.
CVE-2025-9809 1 Libretro 2 Libretro, Libretro-common 2025-12-08 9.8 Critical
Out-of-bounds write in cdfs_open_cue_track in libretro libretro-common latest on all platforms allows remote attackers to execute arbitrary code via a crafted .cue file with a file path exceeding PATH_MAX_LENGTH that is copied using memcpy into a fixed-size buffer.
CVE-2023-39786 1 Tenda 3 Ac8 Firmware, Ac8v4, Ac8v4 Firmware 2025-12-08 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.
CVE-2023-39784 1 Tenda 3 Ac8 Firmware, Ac8v4, Ac8v4 Firmware 2025-12-08 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function.
CVE-2023-39785 1 Tenda 3 Ac8 Firmware, Ac8v4, Ac8v4 Firmware 2025-12-08 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.
CVE-2023-40891 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
CVE-2023-40894 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
CVE-2023-40896 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-48194 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 6.3 Medium
Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. After executing set_client_qos, control over the gp register can be obtained.
CVE-2023-40893 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-40895 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-40899 1 Tenda 3 Ac8, Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40898 1 Tenda 3 Ac8, Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
CVE-2023-40897 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
CVE-2023-40892 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.