Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Receiver, which may lead to local privlidge escalation from the `monitor` user to root

Project Subscriptions

No data.

Advisories

No advisories yet.

Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

Thu, 05 Mar 2026 02:15:00 +0000

Type Values Removed Values Added
Description Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Receiver, which may lead to local privlidge escalation from the `monitor` user to root
Title Multiple SUID Root Binaries in `monitor` User Home Directory Leading to Potential Local Privilege Escalation
Weaknesses CWE-269
References
Metrics cvssV4_0

{'score': 8.6, 'vector': 'CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N'}


Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: Gridware

Published:

Updated: 2026-03-05T01:24:50.411Z

Reserved: 2026-03-04T07:53:45.786Z

Link: CVE-2026-29124

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Received

Published: 2026-03-05T02:16:51.687

Modified: 2026-03-05T02:16:51.687

Link: CVE-2026-29124

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses