Search Results (3248 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-2930 2026-02-22 6.3 Medium
A vulnerability was identified in Tenda A18 15.13.07.13. The affected element is the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. Such manipulation of the argument boundary leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
CVE-2026-2871 2026-02-22 8.8 High
A weakness has been identified in Tenda A21 1.0.0.0. This affects the function fromSetIpMacBind of the file /goform/SetIpMacBind. This manipulation of the argument list causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.
CVE-2026-2883 2026-02-22 8.8 High
A vulnerability was determined in D-Link DWR-M960 1.01.07. Impacted is the function sub_427D74 of the file /boafrm/formIpQoS. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2026-2929 2026-02-22 8.8 High
A vulnerability was determined in D-Link DWR-M960 1.01.07. Impacted is the function sub_453140 of the file /boafrm/formWlAc of the component Wireless Access Control Endpoint. This manipulation of the argument submit-url causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
CVE-2026-2928 2026-02-22 8.8 High
A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_452CCC of the file /boafrm/formWlEncrypt of the component WLAN Encryption Configuration Endpoint. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
CVE-2026-2927 2026-02-22 8.8 High
A vulnerability has been found in D-Link DWR-M960 1.01.07. This vulnerability affects the function sub_462590 of the file /boafrm/formOpMode of the component Operation Mode Configuration Endpoint. The manipulation of the argument submit-url leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2026-2926 2026-02-22 8.8 High
A flaw has been found in D-Link DWR-M960 1.01.07. This affects the function sub_4237AC of the file /boafrm/formLteSetup of the component LTE Configuration Endpoint. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
CVE-2026-2925 2026-02-22 8.8 High
A vulnerability was detected in D-Link DWR-M960 1.01.07. Affected by this issue is the function sub_42B5A0 of the file /boafrm/formBridgeVlan of the component Bridge VLAN Configuration Endpoint. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
CVE-2026-2910 2026-02-22 8.8 High
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
CVE-2026-2909 2026-02-22 8.8 High
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
CVE-2026-2908 2026-02-22 8.8 High
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
CVE-2026-2907 2026-02-22 8.8 High
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
CVE-2026-2906 2026-02-22 8.8 High
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
CVE-2026-2905 2026-02-22 8.8 High
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
CVE-2026-2886 2026-02-21 8.8 High
A weakness has been identified in Tenda A21 1.0.0.0. This affects the function set_device_name of the file /goform/SetOnlineDevName. This manipulation of the argument devName causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.
CVE-2026-2885 2026-02-21 8.8 High
A security flaw has been discovered in D-Link DWR-M960 1.01.07. The impacted element is the function sub_469104 of the file /boafrm/formIpv6Setup. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.
CVE-2026-2884 2026-02-21 8.8 High
A vulnerability was identified in D-Link DWR-M960 1.01.07. The affected element is the function sub_41914C of the file /boafrm/formWanConfigSetup of the component WAN Interface Setting Handler. The manipulation of the argument submit-url leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
CVE-2026-2882 2026-02-21 8.8 High
A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_46385C of the file /boafrm/formDosCfg. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.
CVE-2026-2881 2026-02-21 8.8 High
A vulnerability has been found in D-Link DWR-M960 1.01.07. This vulnerability affects the function sub_425FF8 of the file /boafrm/formFirewallAdv of the component Advanced Firewall Configuration Endpoint. Such manipulation of the argument submit-url leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2026-2877 2026-02-21 8.8 High
A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.