| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Crestron Electronics DM-TXRX-100-STR devices with firmware before 1.3039.00040 have a hardcoded password of admin for the admin account, which makes it easier for remote attackers to obtain access via the web management interface. |
| WordPress before 4.5.3 allows remote attackers to bypass intended password-change restrictions by leveraging knowledge of a cookie. |
| Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges. |
| A vulnerability in the Cisco Intercloud Fabric (ICF) Director could allow an unauthenticated, remote attacker to connect to internal services with an internal account. Affected Products: Cisco Nexus 1000V InterCloud is affected. More Information: CSCus99379. Known Affected Releases: 2.2(1). |
| The "lost password" functionality in b2evolution before 6.7.9 allows remote attackers to reset arbitrary user passwords via a crafted request. |
| Mail in Apple iOS before 8 does not prevent sending a LOGIN command to a LOGINDISABLED IMAP server, which allows remote attackers to obtain sensitive cleartext information by sniffing the network. |
| The QuickType feature in the Keyboards subsystem in Apple iOS before 8.1 collects typing-prediction data from fields with an off autocomplete attribute, which makes it easier for attackers to discover credentials by reading credential values within unintended DOM input elements. |
| The kadm5_randkey_principal_3 function in lib/kadm5/srv/svr_principal.c in kadmind in MIT Kerberos 5 (aka krb5) before 1.13 sends old keys in a response to a -randkey -keepold request, which allows remote authenticated users to forge tickets by leveraging administrative access. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded application password, which makes it easier for remote authenticated users to obtain application-file access via unspecified vectors. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool 1.0.16 and earlier has a hardcoded database password, which makes it easier for local users to gain privileges by leveraging cabinet access. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded service password, which makes it easier for remote attackers to obtain access via unspecified vectors. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 allows local users to obtain potentially sensitive information by reading a temporary (1) debugging file or (2) developer file. |
| The web management interface on Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 has a default password of admin for the admin account and a default password of password for the medialink account, which allows remote attackers to obtain administrative privileges by leveraging a Wi-Fi session. |
| SolarWinds Log and Event Manager before 6.0 uses "static" credentials, which makes it easier for remote attackers to obtain access to the database and execute arbitrary code via unspecified vectors, related to HyperSQL. |
| GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Precision THUNIS-800+ has a default password of (1) 1973 for the factory default System Utilities menu, (2) TH8740 for installation using TH8740_122_Setup.exe, (3) hrml for "Setup and Activation" using DSASetup, and (4) an empty string for Shutter Configuration, which has unspecified impact and attack vectors. NOTE: since these passwords appear to be used to access functionality during installation, this issue might not cross privilege boundaries and might not be a vulnerability. |
| The virDomainGetXMLDesc API in Libvirt before 1.2.11 allows remote read-only users to obtain the VNC password by using the VIR_DOMAIN_XML_MIGRATABLE flag, which triggers the use of the VIR_DOMAIN_XML_SECURE flag. |
| The generate_password function in Moodle through 2.4.11, 2.5.x before 2.5.9, 2.6.x before 2.6.6, and 2.7.x before 2.7.3 does not provide a sufficient number of possible temporary passwords, which allows remote attackers to obtain access via a brute-force attack. |
| Cisco WebEx Meetings Server 1.5 presents the same CAPTCHA challenge for each login attempt, which makes it easier for remote attackers to obtain access via a brute-force approach of guessing usernames, aka Bug ID CSCuj40321. |
| Monstra 3.0.1 and earlier uses a cookie to track how many login attempts have been attempted, which allows remote attackers to conduct brute force login attacks by deleting the login_attempts cookie or setting it to certain values. |