| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Apache Hadoop 2.7.4 to 2.7.6, the security fix for CVE-2016-6811 is incomplete. A user who can escalate to yarn user can possibly run arbitrary commands as root user. |
| In Apache HTTP Server 2.4.17 to 2.4.34, by sending continuous, large SETTINGS frames a client can occupy a connection, server thread and CPU time without any connection timeout coming to effect. This affects only HTTP/2 connections. A possible mitigation is to not enable the h2 protocol. |
| When using PySpark , it's possible for a different local user to connect to the Spark application and impersonate the user running the Spark application. This affects versions 1.x, 2.0.x, 2.1.x, 2.2.0 to 2.2.2, and 2.3.0 to 2.3.1. |
| In Docker Skeleton Runtime for Apache OpenWhisk, a Docker action inheriting the Docker tag openwhisk/dockerskeleton:1.3.0 (or earlier) may allow an attacker to replace the user function inside the container if the user code is vulnerable to code exploitation. |
| In PHP Runtime for Apache OpenWhisk, a Docker action inheriting one of the Docker tags openwhisk/action-php-v7.2:1.0.0 or openwhisk/action-php-v7.1:1.0.1 (or earlier) may allow an attacker to replace the user function inside the container if the user code is vulnerable to code exploitation. |
| WebCore/platform/network/soup/SocketStreamHandleImplSoup.cpp in the libsoup network backend of WebKit, as used in WebKitGTK+ prior to version 2.20.0 or without libsoup 2.62.0, unexpectedly failed to use system proxy settings for WebSocket connections. As a result, users could be deanonymized by crafted web sites via a WebSocket connection. |
| webkitFaviconDatabaseSetIconForPageURL and webkitFaviconDatabaseSetIconURLForPageURL in UIProcess/API/glib/WebKitFaviconDatabase.cpp in WebKit, as used in WebKitGTK+ through 2.21.3, mishandle an unset pageURL, leading to an application crash. |
| Rondaful M1 Wristband Smart Band 1 devices allow remote attackers to send an arbitrary number of call or SMS notifications via crafted Bluetooth Low Energy (BLE) traffic. |
| This vulnerability allows remote attackers to escalate privileges on vulnerable installations of Samsung Members Fixed in version 2.4.25. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the handling of Intents. The issue lies in the ability to send an Intent that would not otherwise be reachable. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the application. Was ZDI-CAN-5361. |
| An issue was discovered in Open Ticket Request System (OTRS) 6.0.x through 6.0.7. A carefully constructed email could be used to inject and execute arbitrary stylesheet or JavaScript code in a logged in customer's browser in the context of the OTRS customer panel application. |
| A Remote Command Execution (RCE) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the execution of arbitrary commands via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140. |
| ASUS HG100 devices allow denial of service via an IPv4 packet flood. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known |
| A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known. |